Top hung window or side opener? Three choices at 905 × 965 mm
Three white Crystal windows in the JJ range have a size option labelled 905 mm × 965 mm. One gives you a clear top opener above fixed glass, another has the same arrangement with obscure glazing, and the third opens at the side beside a fixed pane. Sending a merchant the dimensions and the word “white” leaves all three on the table. Even a clear photograph of the old window can leave the choice unresolved if it was taken with the sash shut.
The quickest way to narrow the order is to answer two questions independently. Where should the glass move when someone opens the window? What should someone looking through the closed window be able to see? This guide follows those decisions through a pair of neighbouring rooms. It deals with upright casement windows in a wall. A top-hung roof window belongs on a different specification.
Read the drawing as someone standing outside
A light is a glazed section of the window. On a top opener over a fixed light, the upper sash opens and the lower glazed section stays in place. A horizontal frame member separates the two. On a side opener next to a fixed light, one sash opens beside the stationary section, with a vertical division between them. Trace that division on the drawing before looking at handles or finishes. It is the feature most easily recognised from across a room after installation.
Crystal’s JJ listings describe the handing from outside. For a replacement, take a photograph facing the building and mark the room name on it. If you can only photograph from inside, write “inside view” on the image itself. An unlabelled phone photo passed from homeowner to fitter to merchant can reverse the intended side by the time someone places the order. A top opener has no left-versus-right choice in the same sense, but the viewing convention matters as soon as you compare it with a side-hung alternative.
Draw the desired arrangement twice if the two rooms are adjacent. A matching outer frame size will line up the edges on the elevation. It cannot align a horizontal division in one frame with a vertical division in another. Mark the proposed bar on a photograph of the pair and look at it from the garden before accepting a change. The Crystal casement window illustrations are a useful starting point for recognising the layouts.
Three lines a buyer could enter for the same size
The clear top-hung window over a fixed light is JJ code 152359 in the 905 × 965 mm option. Use this as the starting point where the view through the lower glass matters and the upper opening suits the room. If the customer wants an uninterrupted view at eye level while seated, ask where that horizontal division will fall relative to the finished floor and chair. The frame dimensions alone will not locate it accurately.
The obscure-glazed top opener over a fixed light is JJ code 152348 in the same size. This is a separate product line, so start with the obscure version when privacy is on the brief. Two saved baskets can look remarkably alike when the colour, dimensions and number of units match. Put the glazing choice on the room schedule in words rather than relying on a small difference between product thumbnails.
The left-hand side-hung window beside a fixed light is JJ code 152268 at 905 × 965 mm with clear glazing. It changes the position of the fixed glass and the movement of the opening sash. A request for an opening section beside the view pane points towards this arrangement. Confirm the opening side against the external elevation. The fact that a side opener is available at the required size is a reason to compare its drawing, not evidence that it fulfils the same function as the upper sash.
Compare Crystal uPVC window layouts
A worked order for a utility room and cloakroom
Suppose the fitter has specified two finished units, each 905 mm wide and 965 mm high overall, including the cill. Treat those as confirmed order dimensions for this example. The utility faces a planted border and the owner wants to see out while standing at the worktop. The cloakroom faces a shared route and the owner wants privacy. Seen from the garden, the owner wants the same horizontal division in both frames.
For the utility, shortlist one 152359 with clear glass. For the cloakroom, shortlist one 152348 with obscure glass. Both have an upper opener and fixed glass below. Ask for the dimensioned elevations to confirm that the horizontal members align as intended and check the proposed glass against the privacy requirement. The useful purchase instruction is two lines of quantity one, each with a room name. Quantity two on the clear line gives the correct number of white frames while leaving the cloakroom decision completely unfulfilled.
Now suppose the utility worktop is deep and the occupier finds the proposed upper handle difficult to reach. Mark its intended height on the wall and try reaching the mark from the place the user would normally stand. If the trial is uncomfortable, ask for the handle position on the side-hung alternative and compare again. Changing to code 152268 may improve operation for that particular person, but also introduces a vertical division. Let the owner choose between those two actual elevations before the revised quote is accepted.
Give the installer the two room uses as well as the order codes. A cloakroom may have existing extract ventilation and the utility may already have a particular opening arrangement. The installer needs to know what is being retained or changed. A window that meets the visual brief still needs checking against the project’s ventilation, glazing and other requirements. Keep the decision about room suitability with the person assessing the installation.
Check what the dimensions include
These Crystal listings state that the cill is included in the overall product height. If your fitter has written “965 mm overall including cill”, record that wording on the order. Adding a separate assumed cill depth to that figure would change the height you asked the merchant to supply. If the note says “frame above cill”, seek clarification before choosing the nearest size. A difference in the reference point can survive several rounds of price comparison unnoticed.
Write “width” and “height” beside the numbers on your drawing. For instance, 905 wide by 965 high is a taller-than-wide rectangle. A supplier quoting a rectangle 965 wide by 905 high is pricing a different shape despite using the same two numbers. Draw a short dimension line across the head and another down the jamb. If you are starting from a masonry opening or old visible glass, use our guide to measuring for uPVC windows before asking the installer to agree a finished frame size.
There is a second trap if a similar room needs a different height. Within these top-over-fixed lines, 905 × 1040 mm clear is code 152362 and its obscure counterpart is 152351. A change to that size adds 75 mm to the nominal height with the width held constant. It does not follow that the top sash gains 75 mm of opening. Request that size’s elevation if the height of the sightline, handle or moving glass matters. Our uPVC window sizes guide explains how to compare the wider range.
Look beyond the opening on the drawing
Stand outside and identify anything in front of the proposed moving section. A downpipe close to a side jamb, a projecting eave above the head or a frequently used path can change the choice. Give the installer the position and distance of the obstruction relative to the outside face of the frame. The installer can compare it with the sash travel for the exact unit. There is no reliable way to calculate the projection from the overall frame height alone.
Inside, test access with the room in everyday use. Put the draining board, mixer tap or tall item on the worktop back where it normally stands. Note whether a blind will hang across the handle or above it. It is easy to approve a comfortable reach in an empty room and then lose it once a deep worktop is fitted. Ask how the external glass will be cleaned as well, especially for the stationary lower pane at an upper level.
Questions worth settling before checkout
Does a top-hung window count as an escape window?
The hinge description alone cannot establish that. Where the room requires an escape opening, ask the installer to check the effective unobstructed opening and its position against the requirements for the property. A fixed lower pane contributes to the outside dimensions while adding nothing to the clear escape opening. In England, the Planning Portal guidance on replacement windows sets out the issues that need consideration, including escape and ventilation. Check the applicable guidance in the nation where the work is being done.
Does obscure glass guarantee the privacy I want?
Start with what you need screened and from where. A person walking past at a distance and someone standing immediately outside after dark present different viewing conditions. Ask for the specific pattern or sample offered with the selected code if that distinction matters. Look at it with light behind it as well as in daylight. The product description “obscure” identifies the glazing choice without promising a particular appearance under every lighting condition.
Should I order a whole unit if the existing sash only sticks?
First have the existing window assessed. The replacement lines compared here are complete window units. A sticking handle or a sash that catches tells you little on its own about whether a whole frame needs changing. If the installer recommends a repair, the information needed for the parts will differ from the dimensions of a replacement frame. Keep the room survey, the repair enquiry and any full-window quotation clearly labelled.
Put the room names on the order
For the matching pair in the original brief, the order is one 152359 clear unit for the utility and one 152348 obscure unit for the cloakroom, each 905 mm wide by 965 mm high including cill. Attach the approved outside elevations and note that both have upper opening sashes. If the owner chooses the side opener after the reach test, amend the utility drawing and its code together. The person checking the delivery can then identify each unit before either is carried to the wrong room.