Towel rail pipe centres: how to measure for a replacement
A 500 mm wide towel rail can have connections 450 mm apart. A 600 mm wide one can have them 444 mm apart. Those are the figures for two real chrome rails in the JJ range, the Nuie Piazza HL382 and Eton HL376. The wider rail actually has the narrower connection spacing. If your bathroom floor is already tiled and the pipes are staying put, that six-millimetre difference is worth discovering before either model goes in the basket.
Towel rail pipe centres describe the distance from the middle of one connection to the middle of the other. Start by finding out which two points you are comparing. The centres of the pipes coming out of the floor, the centres of the valve outlets and the centres of the threaded openings on the rail can represent different pairs of points. They coincide in some arrangements. In others the valves change the direction or position of the connection. A photograph showing the entire route from each pipe into the rail helps a plumber interpret your measurement.
Measure the spacing without taking the rail apart
Make a sketch as if you were facing the rail. Draw the visible pipes, the valve bodies and the two places where they enter the radiator. Mark whether the pipes emerge from the wall or the floor. Then mark the endpoints of each measurement on the sketch. A dimension labelled “450 mm across old pipes at floor” conveys far more than a text message saying “rail is 450”. Leave existing plumbing assembled while collecting measurements for a quote.
If the exposed pipes are parallel and the same outside diameter, measuring from the left edge of one to the left edge of the other gives the same separation as measuring centre to centre. This is often easier than guessing the midpoint of a round copper pipe with a tape. Take the measurement across the pipes at the same height, where both are straight. Measure the pipe itself rather than the collars covering holes in the tiles. A collar can sit off-centre or have a completely different diameter.
As a cross-check, imagine two straight pipes of 15 mm outside diameter. If the total distance across their outside edges is 465 mm, subtract one diameter to get 450 mm between centres. If you measured the clear gap between their nearest edges instead, you would expect to see 435 mm and would add one diameter. Those examples apply to the stated equal pipe diameters. Mixed pipe sizes, angled tails or valves hiding the pipework are reasons to photograph the detail and have the installer confirm it.
Three chrome towel rails with quite different connections
The 500 mm wide Piazza towel rail is a nine-bar model measuring 950 mm high. Nuie's HL382 sheet gives 450 mm centres for its upright configuration. On the drawing, keep the 500 mm body dimension across the top and put the 450 mm figure against the two connections. That leaves no doubt which number to use for wall space and which number the plumber needs when checking the valve arrangement.
The 600 mm wide Eton towel radiator measures 1,200 mm high. The ROXOR technical sheet for HL376 gives 444 mm pipe centres. Compared with the Piazza, the Eton adds 100 mm of body width and 250 mm of height while bringing the two connection centres 6 mm closer together. A rule of thumb such as deducting 50 mm from the rail width works for the Piazza in this comparison. It would put the Eton connections at 550 mm, a substantial error.
The chrome Elgin heated towel rail occupies a third footprint at 1,080 mm high by 550 mm wide. Its HL336 technical sheet lists just 50 mm pipe centres. Put a ruler across 50 mm and across 450 mm on your paper sketch: the Elgin calls for a radically different connection arrangement from the Piazza despite the similarity in their overall widths. Ask for the dimensioned drawing showing the location of the connection pair on the body before deciding where the rail would sit relative to the existing pipes.
| Chrome rail | Height × width | Connection centres | JJ code |
|---|---|---|---|
| Piazza HL382 | 950 × 500 mm | 450 mm | 154419 |
| Eton HL376 | 1,200 × 600 mm | 444 mm | 154418 |
| Elgin HL336 | 1,080 × 550 mm | 50 mm | 154403 |
Worked replacement decision for a tiled bathroom
Suppose you have 620 mm of clear wall between a boxed-in pipe and the side of a vanity. The existing rail sits roughly in the middle. The exposed pipes measure 450 mm centre to centre and rise from a floor you intend to keep. Your priorities are to retain that floor, allow a drawer to open fully and gain enough hanging space for two people. You have measured the wall at rail height and photographed both valves. Which rail earns a place on the quotation?
Start with the Piazza. Its 500 mm body leaves 120 mm in total within the 620 mm opening. If the rail were centred in the opening, that would be 60 mm either side before allowing for fittings. Its stated centres match the 450 mm figure on your sketch, so it is a sensible first candidate for the installer. It still needs two checks. The existing pipe pair may sit to one side of the opening, and the valve bodies may bring their outlets to different positions from the pipes below.
Try the same exercise for the Eton. A 600 mm body leaves just 20 mm of total width, or 10 mm each side if centred. The first question is whether you can reach the controls and clear the furniture in that layout. The second is whether your plumber can connect the 444 mm rail to the existing arrangement. Splitting the six-millimetre difference on paper gives three millimetres each side if both pairs share a midpoint. That arithmetic describes the mismatch. It gives no assurance that a rigid pipe or valve can accommodate it.
The Elgin leaves 70 mm in total across the opening. Its close-spaced connections make it a different proposition if the pipe exits must stay 450 mm apart. Ask the plumber to price how the pipes and valves would meet the rail and to show what would remain visible. At that point you have a useful buying decision: request a firm fitted price for the Piazza first, consider the Eton if the furniture and valves allow, and reserve the Elgin for a layout where its connection arrangement makes sense. The important saving may be in keeping the tiled floor intact rather than in the ticket price of the rail.
Check how far the rail comes out from the wall
A plan view picks up clashes that are easy to miss in a front elevation. On the Eton HL376 data sheet, the product depth is 40 mm, the wall-to-centre-of-tappings dimension is 85 mm and the maximum projection is 110 mm. These describe three different things. A customer working solely from “40 mm deep” could reserve far too little space in front of the finished wall. On your sketch, draw the finished tile face first and measure the projection out from that line.
In the example bathroom, open the vanity drawer and mark its nearest point to the proposed rail. Include a hanging towel when judging how convenient the position would be in everyday use. Look at the door handle as well as the door edge, particularly if the rail will sit behind the door. A rail can clear the door when it is shut and still occupy the path the handle follows while opening. These are useful checks even if you are keeping the old rail's width.
What if the bathroom is being retiled?
Tell the installer which dimensions came from the old tile face, which came from the bare wall and where the new finished face is expected. The distance between two parallel pipes may stay the same while their distance from the finished wall changes. This matters when comparing wall-to-tapping dimensions. A photo of the tape against bare plaster is useful only if the person interpreting it knows the tiles and adhesive have yet to go on.
Match the heat output as well as the metalwork
Where a towel rail also heats the bathroom, ask your heating installer what output the room requires at your system's operating conditions. Compare outputs at the same temperature difference. For example, the Eton HL376 sheet lists 253 watts at ΔT50 and 132 watts at ΔT30. The Elgin HL336 lists 336 and 170 watts respectively. Using the higher figure for one and the lower figure for the other gives a misleading comparison. Our radiator buying guide explains how to read output figures across different radiator types.
Suppose the installer has already calculated a requirement of 200 watts at ΔT30 for a particular space. In that example neither the Eton at 132 watts nor the Elgin at 170 watts supplies all of the calculated requirement on its own, even though both exceed 200 watts at ΔT50. That could move the decision towards a separate room radiator and a rail for towels. You can price those as separate items in the radiator range once the installer has confirmed what each needs to deliver.
Questions to settle before placing the order
Can I keep the existing valves?
Give the plumber the make and model of the proposed rail, a clear photograph of each valve and the direction of the pipe entering it. Ask whether the existing valve arrangement will meet the new tappings and leave the controls accessible. Record the answer on the quote, including any replacement valves or tails. Two prices for the same rail can represent different fitted jobs if only one includes those items.
Will the old bracket holes line up?
Connection centres tell you where the water connections are. Bracket positions are separate dimensions on the mounting drawing. If retaining existing tiles matters, send a photograph showing the present fixing points and ask which will be covered by the new rail. Two rails can connect to the same pipe positions while leaving an old fixing hole visible between the bars. Agree how that will be finished before choosing purely on the front view.
What should I send to the merchant?
Include a front view, a side view and a sketch with the pipe centres, finished wall width and available height marked in millimetres. Add the model code, finish, door or drawer clearance and any limits on moving pipes. If your tape reading sits between two marks, say so. A merchant can obtain the correct product drawing for the plumber to check. Guessing the last few millimetres to match a product on the screen removes exactly the information the plumber needs.
For a straightforward replacement, keep the pipe measurements, valve arrangement and product drawing together until the installer has signed off the choice. In the 620 mm opening above, the Piazza is the first model worth pricing because its body and connection spacing suit the initial survey. The finished-wall offset, accessible valves and room heat requirement settle whether it is the right one to order.