Shower Bath Sizes and Handing: Measure Before You Order

A shower bath order needs more than one measurement. Nominal length, maximum width, the showering-end position and the finished installation height all describe different parts of the job. Getting them clear before purchase helps prevent the familiar problem of a bath that fits the wall but faces the wrong way or leaves no useful space beside it. This guide explains how to prepare a measured brief and confirm left- or right-hand selection with your installer.


By JJ Building Materials
7 min read

Shower Bath Sizes and Handing: Measure Before You Order - JJ Building Materials

A shower bath order needs more than one measurement. Nominal length, maximum width, the showering-end position and the finished installation height all describe different parts of the job. Getting them clear before purchase helps prevent the familiar problem of a bath that fits the wall but faces the wrong way or leaves no useful space beside it. This guide explains how to prepare a measured brief and confirm left- or right-hand selection with your installer.

Record the room before choosing a nominal size

Measure the available wall length in more than one position and note whether the surfaces are finished. An unfinished wall measurement should not be treated as the final tiled opening. Record projections such as boxing, window ledges and pipe covers separately. If the room is being stripped, ask the installer which measurements can be confirmed now and which depend on the new wall and floor build-up.

Label the drawing with a clear viewing direction. Mark the door, window, basin, toilet and proposed shower wall so the plan cannot be accidentally read as its mirror image. Photographs help, but a dimensioned plan is the more useful ordering document. Browse the shower baths range with that plan beside you, keeping a separate entry for each candidate rather than mixing dimensions from several models.

Do not select a larger bath simply because the wall seems long enough. Check the space needed to bring the bath into position, complete the connections and use the room afterwards. A product can fit its intended recess while being difficult to carry through a landing or turn through a doorway. Measure that route before committing to delivery.

Understand what the catalogue length tells you

Lengths such as 1500mm, 1600mm and 1700mm are useful starting points for shopping. They are not a substitute for the exact technical drawing. The product's actual dimensions, permitted installation arrangement and surrounding finishes determine the space required. Keep the manufacturer's code attached to every measurement so a nominal description does not become an assumed construction dimension.

For a shorter layout, compare the 1500mm left-hand P-shaped bath with the 1500mm left-hand square shower bath. Both occupy the same broad length category, but their front profiles and showering zones are different. A room that works with one may not work equally well with the other. Draw each complete outline rather than changing only a number at the end of a rectangle.

If more length is available, the 1600mm left-hand P-shaped bath gives another option to investigate. Consider whether the additional bathing length offers a useful improvement and whether it affects the route past the bath. A larger nominal size should solve a real requirement, such as bathing comfort, rather than simply filling every available millimetre.

Nuie Shower Baths 1500mm Left Hand P-shaped Bath Contemporary White Acrylic 415x850x415mm
Nuie Shower Baths 1500mm Left Hand P-shaped Bath Contemporary White Acrylic 415x850x415mm — check the selected variant for dimensions, finish and supplied components.

Measure the widest part and its position

For a shaped shower bath, record the maximum width at the showering end and the narrower width along the rest of the bath. Also establish where the change in profile occurs. That position can be just as important as the maximum dimension when a basin or toilet sits beside the bath. An enlarged end that starts sooner may obstruct a fitting that another model clears.

Mark the footprint on the floor and test the normal movements around it. Open the room door and nearby drawers. Stand where you would dry yourself or help someone use the bath. Allow for the screen and controls as physical objects, not just thin lines on a plan. This exercise often reveals a layout problem that a list of dimensions does not make obvious.

Distinguish external measurements from usable internal space. Rim width and the shape of the bath walls influence how much room a person actually has. Do not describe the external width as the standing area. Where comfort is a deciding factor, compare the manufacturer's internal drawing or view a representative model before ordering. Ask for clarification if only broad outer dimensions are available.

Confirm left and right from the exact drawing

Handing identifies a specific arrangement of the shaped bath. It should be confirmed from the manufacturer's plan for the selected code, with the same orientation shown on your room drawing. Avoid relying on phrases such as 'left as I walk in' unless the supplier has confirmed that this matches the manufacturer's convention. Two people looking from opposite sides can use the same word for different layouts.

Place the product drawing over the room plan and mark the showering end, wall edges and exposed front. Then write the selected code in the quotation and order. Ask the installer to check the same drawing before purchase. This creates one shared reference and avoids a last-minute assumption based on the appearance of a photograph or a shortened item description.

Compare a paired option only after identifying its handed equivalent. The 1700mm left-hand P-shaped bath, for example, should be evaluated with its own drawing and specification. Do not assume that a supplier's image is a photograph of the selected hand; some listings use a representative image. The code and verified drawing should settle the decision.

Include the screen in the measured arrangement

The screen needs a suitable fixing surface and the correct relationship with the bath rim. Ask which screen is approved for the chosen bath and how it opens or moves, if applicable. Mark its movement on the plan alongside the basin, taps and any window furniture. An apparently clear bath footprint can still leave a screen colliding with a neighbouring fitting.

If you are considering the 1500mm left-hand square shower bath set, check the supplied screen and side panel against the current contents list. A coordinated set reduces the number of separate selections, but it does not remove the need to check the room. The wall must still accommodate the screen's fixing and adjustment requirements, and the installation must preserve practical access.

Measure from the correct finished surfaces for the screen. A fixing height or adjustment range should come from its own instructions, not be borrowed from a different enclosure. If walls are out of plumb, ask the installer whether the approved adjustment can accommodate them. Do not assume that extra sealant will compensate for a poorly matched or incorrectly positioned screen.

Nuie 1500mm Left Hand Square Shower Bath Contemporary White Acrylic 390x850x390mm
Nuie 1500mm Left Hand Square Shower Bath Contemporary White Acrylic 390x850x390mm — check the selected variant for dimensions, finish and supplied components.

Check height, waste and service access together

The bath body depth is not the same as the installed height above the finished floor. The support system, panel and plumbing arrangement all contribute to the finished installation. Have the installer confirm these together. A number repeated in a product title may describe a body dimension rather than the height you will step over once the bath is fitted.

The waste connection needs a practical route and sufficient space for the specified trap and pipework. Existing pipes should be inspected before assuming they can serve the replacement bath unchanged. The waste position may differ even when the new bath has the same nominal length as the old one. Keep access for inspecting and maintaining these connections in the plan.

Coordinate the front panel with the installed height. Nuie's fitting guidance for its standard bath arrangement specifically relates foot adjustment to panel height; the correct instructions for the selected bath remain the reference. Do not order a panel purely from the bath's headline length. Our shaped bath panel compatibility guide explains the separate profile and matching checks.

Make the order sheet unambiguous

Use one line for the bath with its full code, hand, nominal size and confirmed actual dimensions. Add separate lines for the screen, front panel, any exposed end panel, waste and filler. Mark whether each item is included in a set or supplied separately. This makes the order easier to check and prevents a similar-looking component being substituted without noticing a compatibility difference.

For a larger room, a 1800mm left-hand square shower bath set may be worth considering, but repeat the same checks rather than assuming that extra room eliminates them. Delivery access, screen movement and service access still matter. A long bath can be particularly awkward to turn through a tight landing even when the bathroom itself is generous.

Before payment, compare the quotation with the agreed plan and have any conflicting descriptions resolved. If the title says one hand while the detailed contents say another, do not choose whichever wording seems more likely. Ask the supplier to confirm the exact code in writing. Keep that confirmation with the order and check the delivered labels before installation begins.

Nuie Shower Baths 1800mm Left Hand Square Shower Bath Set Contemporary White Acrylic
Nuie Shower Baths 1800mm Left Hand Square Shower Bath Set Contemporary White Acrylic — check the selected variant for dimensions, finish and supplied components.

Shower bath measurement FAQs

Can I order from the length of my existing bath?

Use it only as an initial guide. Confirm the new bath's actual dimensions, profile, handing, waste position and installation requirements. The old bath may hide unfinished surfaces or pipework that changes the available space.

Does 1700mm always mean exactly 1700mm overall?

No. Nominal size is a shopping category, and the precise technical dimensions can differ. Use the drawing for the exact product code when planning the opening and surrounding finishes.

How do I avoid ordering the wrong hand?

Match the manufacturer's plan to your room plan and identify the showering end and wall edges. Have the installer confirm the selected code. Avoid relying solely on a photograph or an informal left/right description.

Should I measure before or after tiling?

Agree the installation sequence with the installer. Record the current measurement and the proposed finished build-up clearly, then use the dimensions required by the bath and screen instructions. Do not mix finished and unfinished measurements.

What if the product information conflicts?

Pause that selection and request confirmation of the code, hand, dimensions and supplied components. A clear answer before ordering is more useful than trying to adapt the bathroom around an uncertain product after delivery.