Measuring for a Door Stop: Projection, Height and Clearance
The most useful door stop measurement is the one that relates to the actual contact point. Overall size, buffer height, projection and base diameter describe different things, and confusing them can lead to a fitting that misses the door or allows the handle to hit the wall first. This guide explains how to prepare a door-stop measurement brief before selecting a Frisco Eclipse product.
The most useful door stop measurement is the one that relates to the actual contact point. Overall size, buffer height, projection and base diameter describe different things, and confusing them can lead to a fitting that misses the door or allows the handle to hit the wall first. This guide explains how to prepare a door-stop measurement brief before selecting a Frisco Eclipse product.
Record the opening as it will be used
Make measurements with the intended door, handle and floor finish in place wherever possible. If the room is still under construction, record what will change and have the installer confirm the final dimensions later. A new floor covering, a different handle or thicker wall finish can alter the clearance. Treat early measurements as provisional when those elements are unresolved.
Draw a simple plan of the doorway and nearby wall, furniture or radiator. Mark the hinge side, the direction of opening and the obstruction you want to protect. Use that sketch when browsing the door stops range. It makes the purpose of each measurement clearer and helps a supplier or installer understand the problem without relying on a single close-up photograph of the existing stop.
Find the first unwanted contact
Move the door gently through its intended opening range and observe what would touch first. Do not force it against the obstruction to establish the limit. The handle may reach the wall before the door face, or a door edge may approach a cupboard. Record the relevant component and location. The stop should be selected to intervene before that contact, with an appropriate margin established by the installer.
Consider more than the most obvious wall. A nearby socket, projecting shelf, radiator valve or piece of furniture may sit within the path. Review the completed room layout and the door's full movement. A stop that protects the wall but allows another fitting to collide with a different object has not solved the complete clearance problem.
Measure handle projection from the correct surface
Handle projection is the distance it extends from the relevant door face, but the final wall clearance also depends on the door angle and stop location. Record the actual handle fitted, including any projecting part that could make contact. Do not use an approximate measurement from a different door merely because the handles look similar. Replacement hardware may have a different reach even within a similar style.
A Frisco Eclipse 76mm linear projection stop and a 76mm knurled projection stop are useful products to compare where that form is being considered. Their stated projection does not remove the need to assess the geometry. Ask the fitter to confirm the proposed mounting plane, contact point and remaining clearance with the actual door and handle.

Distinguish projection from overall length
Read the product's dimensional drawing or confirmed specification. A catalogue size may identify the product family, but it may not describe exactly the dimension you need for the clearance calculation. The base or rose can also influence how the fitting sits against the mounting surface. Ask for clarification if the information does not distinguish these features clearly.
The Frisco Eclipse secret-fix projection door stop has a different fixing arrangement from a face-fix wall door stop. Compare the full dimensions and mounting details rather than treating the nominal length as the only relevant measurement. This is particularly important when replacing an existing fitting where the mounting surface, hole position and available space are already constrained.
Check floor-to-door clearance along the swing
For a floor-mounted stop, measure the clearance under the door at the proposed stopping location. Do not assume it is identical across the whole swing. Uneven floors, thresholds and different coverings can change the gap. Record the finished floor surface and whether any part of the door or its fittings hangs lower than the main leaf.
Compare that clearance with the actual effective contact height of the selected product. The Frisco Eclipse linear floor stop and knurled floor stop are separate options within the floor-mounted range. A number such as 30mm in a title should not be interpreted without checking what it measures. The door needs to contact the intended buffer area, not skim over the stop or strike an unsuitable metal edge.

Record the base footprint
A stop's base needs space as well as height or projection. Measure the available mounting area and note nearby joints, edges, trims or other fixings. A fitting may be small overall yet have a base that does not sit properly on a narrow surface. Review the complete footprint rather than judging it from the body alone.
Floor products such as the Frisco Eclipse half-moon buffer stop and projection buffer floor stop have different forms. Compare how their bases and contact surfaces would sit at the proposed location. A half-moon or shielded shape is not simply a decorative variation if it changes the contact arrangement or the space needed for fixing. Use the actual product information to make that comparison.
Measure from the real mounting plane
A wall stop fixed to skirting begins from a different plane than one fixed to the wall above it. The skirting's projection can therefore affect the remaining distance to the door. Likewise, a floor stop sits on the finished covering, not the structural floor below. Identify the reference surface explicitly in your notes so everyone is using the same starting point.
If the background is irregular, ask the installer how the fitting will sit securely. Do not compensate for an uneven surface by assuming the stop can be tightened until it lies flat. The mounting detail needs to be suitable for the product and substrate. A clear note about the surface can prevent an apparently correct dimension from producing the wrong installed position.
Keep fixing information beside the dimensions
Geometry and fixing suitability belong in the same brief. Record whether the proposed position is on timber, masonry, a hollow wall, tile or another surface, and whether concealed services or floor systems affect drilling. The installer should establish a safe and suitable fixing location. Do not choose a stop first and then assume the room can accept whatever fixing it requires.
Supplied screws or plugs are useful product information, but their presence does not establish suitability for every background. Ask the installer to identify any required alternative fixing and confirm that it is compatible with the stop. Keep the agreed approach with the selected product reference so a later change of mounting type does not bypass those checks.
Use a reversible trial to assess the position
Before permanent fixing, have the installer mark or represent the proposed contact position without damaging surfaces. Move the door carefully and check that the stop would intervene at the intended point. Confirm that the opening remains usable and that the fitting's location is acceptable in the room. A trial is particularly useful where the door approaches a wall at an unusual angle.
Do not test by repeatedly striking a loose product against the door or wall. The purpose is to understand the geometry, not to assess impact performance through an improvised test. If the door's construction or required use makes the contact arrangement uncertain, seek an appropriate specification. A measurement exercise cannot establish a product rating that the manufacturer has not provided.

Replacement measurements need both old and new details
For an existing stop, record its product reference if known, overall form, mounting location and visible fixing arrangement. Photograph it before removal and note why it is being replaced. A damaged buffer, loose fixing and inadequate projection are different problems. The new product should address the actual issue rather than merely cover the same mark on the wall.
Compare the proposed replacement's dimensions with the old installation, including the base footprint and contact point. Existing holes may not suit the new fixing arrangement. Do not assume that two secret-fix stops share the same concealed mechanism or that a similar diameter guarantees compatibility. Have the background assessed if it has been damaged or repeatedly refixed.
Create a final purchase record
A useful record includes the selected product, finish, confirmed dimensions, mounting surface, intended location and the obstruction being protected. Add photographs and the installer's agreed fixing approach where relevant. This can be a short note rather than a technical drawing, provided the references are clear. It helps the person ordering avoid choosing a near-match with a different projection or base.
After fitting, retain the product details and check the door's operation gently. Confirm the intended clearance in the completed room, including any furniture added after installation. If the arrangement changes later, such as through a new handle or floor covering, reassess the stop. A fitting that was correctly measured for one configuration may need review when the surrounding geometry changes.
Frequently asked questions
Is the size in a door stop title always its height?
No. It may refer to projection, diameter or another nominal dimension. Check the complete product specification or drawing and ask for clarification where necessary. Use the dimension that relates to the actual contact and mounting arrangement.
Can I calculate projection from the handle measurement alone?
Not reliably for every doorway. The door angle, mounting plane, stop position and buffer contact all influence clearance. Record the handle projection, then have the complete geometry assessed with the door in its intended opening position.
Should I measure before fitting the new floor?
You can prepare provisional measurements, but the final check should account for the completed floor level and covering. Floor-to-door clearance and the stop's installed height may change. Make those changes explicit before ordering or fixing.
Can a replacement stop use the existing hole?
Only if the new product and fixing arrangement are suitable and the background remains sound. Similar appearance does not establish identical fixings. Compare the product details and have damaged or uncertain fixing locations assessed.
What if the dimensions on the listing conflict?
Ask for confirmation before buying. Do not decide that one number must be correct because it appears in the title. Keep the confirmed measurement and its meaning with the product reference so the installer can assess the right specification.