Will a flexible sun tunnel reach your hallway? Compare three roof kits

A 1.50 m rise can need more than 2.10 m of tube. Compare two hallway layouts and match a FAKRO flexible tunnel to slate, corrugated or high-profile roofing.

By JJ Building Materials
8 min read

Will a flexible sun tunnel reach your hallway? Compare three roof kits - JJ Building Materials

Stand in the darkest part of your hallway and point to the spot where you would like daylight to fall. Now ask the roofer where the collector could sit on the roof. Those two points are the starting measurements for a flexible sun tunnel. The distance between them, what lies in the way and the covering on the roof will tell you far more about which kit to buy than the floor area of the hallway alone.

Consider a bungalow with a window beside the front door. The entrance already gets daylight, but further down the passage the cupboard with the coats and shoes is in shadow. A diffuser centred on the entire hallway would look symmetrical on a plan. Moving it towards the cupboard might do more for the people using the space. The question is whether that position still gives the roofer a practical route to daylight.

Start at the ceiling, then look at the roof

A sun tunnel has three parts you can identify on a drawing. A roof element admits light, a reflective tube carries it through the void and a diffuser spreads it into the room. The visible ceiling fitting does not need a clear view of the sky from below in the way an open lightwell would. That makes sun tunnels worth considering over an internal passage with a loft above it. You still need a continuous, suitable route for the tube between its two ends.

Mark the coat cupboard, ceiling light, loft hatch and door swings on a rough plan. Use a paper circle to try two or three diffuser positions from below. Look at each one from the front door and again from the cupboard. A position competing with a pendant or partly concealed by an open cupboard door may look less attractive in the room than on the drawing. A circle on paper helps choose the position. The installation drawing supplies the actual opening and trim dimensions.

Ask the installer to add the joist direction, obstructions and possible collector positions. A tank immediately above your preferred ceiling position is a different problem from a pipe crossing one proposed route halfway along it. In the first case the diffuser itself might need moving. In the second the installer may be able to compare another collector position or a modest change of route. Do that comparison before ordering a tube on the strength of its nominal length.

What a 2.1 m tube tells you about the route

Take a proposed layout where the two connection points are 1.50 m apart vertically and 0.80 m apart horizontally. A straight line between them is about 1.70 m. The arithmetic is the same as measuring the diagonal of a rectangle: 1.50 squared plus 0.80 squared gives 2.89, whose square root is 1.70. The FAKRO flexible light tunnel specification gives a tube length of 2.1 m for the SF family. This layout is worth taking to the next stage of a survey.

The difference of 0.40 m is not an installation allowance. That straight line is the shortest possible distance between the two points. A real route may need to curve, meet the connections at particular angles or pass an obstruction. Ask the roofer to mark the proposed tube path and verify its length and clearances using the instructions for the kit. A ceiling-to-roof height taken directly above the diffuser misses the offset altogether.

Now move the collector further across the roof so that the horizontal offset becomes 1.60 m. With the same 1.50 m rise, the shortest distance becomes about 2.19 m. Even an unobstructed straight route now exceeds 2.10 m. A bend cannot recover that missing length. At this point compare moving the diffuser, changing the roof position or specifying another manufacturer-approved arrangement. Buying the wider diameter version does nothing to close a length shortfall.

Read the last letter before choosing the roof kit

Three 350 mm FAKRO flexible kits can look much the same from inside the hallway. Each has a 350 × 2,100 mm option at JJ. The important difference for the roofer sits at the upper end, where the flashing must suit the covering. FAKRO lists the pitched-roof SF family for roof slopes from 15° to 60°. Its UK product catalogue distinguishes slate, corrugated and high-profile coverings within that family. Ask for both the covering identification and the measured roof pitch on the quote.

The FAKRO SFL flexible sun tunnel for slate in the 350 mm option is JJ code 117400. FAKRO’s table identifies SFL for slate coverings up to 5 mm. “Slate roof” in an estate agent’s particulars is a starting description. Get the installer to identify what is actually on that slope. A slate-looking interlocking tile should not be ordered against a slate flashing merely because the colour and outline look convincing from the pavement.

For a compatible corrugated covering, the FAKRO SFZ corrugated roof light tunnel in 350 mm is JJ code 117398. FAKRO specifies a covering profile up to 45 mm for SFZ. The relevant figure is the profile of the covering. The overall length of a spare tile, its width across the roof and the thickness at one edge answer different questions. A tile name or reference and a profile drawing will help the roofer identify the correct detail.

The FAKRO SFH high-profile tile sun tunnel in the same diameter is JJ code 117399. FAKRO lists SFH for high-profile coverings up to 120 mm. That upper limit does not turn it into a universal replacement for SFZ. If a quotation simply says “350 mm tunnel for tiles”, have the roofer name the tile and the tunnel suffix together. It costs nothing to correct two letters on an enquiry and can save returning a kit after roof access has been arranged.

Model Roof covering in FAKRO UK catalogue JJ code
SFL Slate up to 5 mm 117400
SFZ Corrugated up to 45 mm profile 117398
SFH High profile up to 120 mm 117399

Compare sun tunnel kits

Choose the route before comparing flexible and rigid tubes

A flexible light tunnel is worth pricing where the ceiling and roof positions do not line up neatly. The freedom to alter the path has a trade-off. Light travels by reflection inside the tube, so taking it the long way around a loft is a poor starting point for a daylight design. Ask the installer to compare the shortest sensible route with the route you first drew. Sometimes moving the ceiling fitting a little still puts daylight where you want it and removes an awkward bend.

Where the roof element can sit almost directly above the ceiling fitting, ask for a rigid sun tunnel option as well. FAKRO distinguishes SF flexible tubes from SR rigid tubes. Keep each system’s length, elbows and available extensions on its own quotation. A figure printed beside a flexible model should not become the assumed reach of a rigid kit of the same diameter. If you also want a view outside or an opening sash, compare the function of pitched roof windows before committing to the ceiling diffuser.

How to compare the installed quotations

For the bungalow example, suppose the installer confirms a 35° slate roof with a covering suitable for SFL and a workable route for the 350 mm kit at the first position. The enquiry can now specify JJ 117400, the diffuser by the coat cupboard and the roof position shown on the survey sketch. One supplier can price that exact kit while the contractor prices access, roof work, fitting and ceiling making good. Put those items beside each other when comparing with a supply-and-fit quotation.

Ask what will be visible indoors when the job is complete. If the diffuser moves away from an existing fitting, will the old light stay in use, be repositioned or leave a patch to finish? Daylight varies through the day and is unavailable after dark. A hallway used for finding keys on a winter evening still needs its lighting plan. Keep any electrical work explicit in the quote so the two contractors are pricing the same finished room.

Give the installer photos of the roof in context as well as the interior. A neighbouring roof, tall tree or chimney can affect which position receives useful daylight. A nominal diameter on a product page cannot predict the brightness on your particular cupboard shelf. Ask the supplier what outcome they expect for the orientation, tube route and time of day that matter to you. An answer tied to those details is more useful than a promise to light a certain number of square metres.

Questions buyers ask before ordering

Can I choose a larger tube to get past a joist?

A wider tube needs more room along its route. If the original difficulty is a narrow space between obstructions, increasing the diameter may make the layout harder. Get the installer to check the roof opening, the whole tube path and the ceiling opening for the exact model. Keep structural changes out of the buying assumption. Another diffuser position may serve the same part of the hallway without changing any framing.

Does a flat-looking collector mean the kit suits a flat roof?

The exposed roof element can have a flat face while the assembly is intended for a pitched roof. Ask whether “flat” on the drawing refers to the glazing, the roof covering profile or the slope of the roof itself. For a genuinely flat-roofed extension, compare the dedicated flat-roof system against that construction. The roof windows and lanterns range also gives you alternative ways of bringing light into the extension if the room design is still open.

What should I send if I cannot identify the tiles?

Send a ground-level photograph showing the roof pattern and any reference from the construction records. If the roofer has an accessible spare tile, a photograph of its face and markings can help with identification. Add the pitch and the position of the proposed collector. A photograph of the hall alone leaves the supplier guessing which of the roof tile profiles the flashing has to meet.

What goes on the order for this hallway?

For the surveyed slate example, the order line is “FAKRO SFL, flexible tube, 350 × 2,100 mm, JJ 117400, one kit”. Keep the approved roof covering, pitch and marked diffuser position with the quotation. If a revised survey moves the collector to the 1.60 m offset in our example, pause that order and revisit the route. The opening in the ceiling may look exactly the same from below, but the standard tube is already shorter than the straight-line distance above it.

Check a sun tunnel specification with JJ