Which flat roof insulation board matches your waterproofing system?

Compare Kingspan TR26, TR27 and Recticel Powerdeck U by waterproofing application. A 24m² extension shows how to turn board dimensions into pack quantities.

By JJ Building Materials
7 min read

Which flat roof insulation board matches your waterproofing system? - JJ Building Materials

“100mm PIR for the extension roof” looks like a perfectly serviceable line on a materials list. Put it into a basket, though, and you can end up with three long boards intended for one waterproofing system or four square boards intended for another. Both packs can say 100mm. They cover different areas, and the roofer may only be able to use one of them.

The quickest way to choose a flat roof insulation board is to find the waterproofing specification first. Ask for the name of the membrane or felt system and how it is to be attached. Then find the insulation product, thickness and board format approved for that build-up. Below, two Kingspan packs and a smaller Recticel board show how those details change the order, even when the outline of the roof stays exactly the same.

Find the line on the drawing that names the waterproofing

A warm flat roof places insulation above the structural deck, beneath the waterproofing. The product you buy for that layer has to work with the layers around it. A drawing might identify the membrane by its trade name while a schedule elsewhere lists the board. Ask the designer or roofing contractor to put the two references together. If you have been given only a thickness and the words “single ply”, there is still a purchasing decision outstanding.

In particular, find out what the term “fixed” refers to. A note about securing the insulation to the deck does not necessarily tell you how the waterproof covering is attached above it. The two operations have different interfaces. An order clerk hearing that the boards will be fixed could reasonably write down the wrong product if the roofer actually intends to bond the membrane to their upper faces. Ask the specific question: how will the waterproofing be attached, and which insulation facing does that system accept?

Three product descriptions that mean different things

For a specification calling for mechanically fixed single-ply waterproofing, the Kingspan Thermaroof TR26 insulation board is a candidate. Kingspan’s TR26 specification identifies the board for use with most mechanically fixed single-ply systems. The word “most” matters. Give the roofer the product name and ask them to check it against the particular membrane schedule. The 100mm variant sold by JJ is 2,400 × 1,200mm, with three boards in a pack. Its product code is 162150.

For fully adhered single-ply waterproofing, the Kingspan Thermaroof TR27 flat roof board is the one of these two products to discuss. Kingspan also identifies uses with partially bonded built-up felt, mastic asphalt and cold liquid-applied systems. These are application families. The designer still needs to identify the specific build-up for your roof. At 100mm, JJ’s TR27 variant is 1,200 × 1,200mm, four to a pack, code 162160. A note that says simply “Thermaroof, one pack” could therefore describe two quite different deliveries.

For a warm roof with a specified bituminous torch-on felt system, consider the Recticel Powerdeck U insulation board. Recticel’s Powerdeck U specification describes a bituminous-coated glass fleece on both sides and identifies this board for that waterproofing application. JJ lists the 100mm option under code 162244, in a 1,200 × 600mm format. Each board covers 0.72m² before cuts. Have the supplier confirm how many of that exact thickness come in the sales unit on your quotation. The coverage of one board alone is insufficient to price a whole roof.

There is a practical distinction here for anyone comparing felt quotations. One contractor may specify a partially bonded built-up felt system while another quotes a particular torch-on system. The word “felt” appears on both documents. It does not settle the choice of board. Ask each contractor to name the approved insulation and any intermediate layer in their own proposal, then compare the completed systems. Treat a change of membrane as a reason to revisit the materials list even if the proposed roof thickness looks the same.

Compare insulation board sizes

Turn the specified board into a pack quantity

Take a simple rectangular roof measuring 6m by 4m in plan. The main field is 24m². For this example, assume the design has already specified a single 100mm insulation layer and separately detailed the edges. That thickness is an example for comparing packs. Your designer’s thermal calculation determines the thickness for your own roof. Draw the actual outline, mark rooflights and outlets, and separate the main field from any additional pieces called for at the perimeter.

Start with the mechanically fixed example and JJ code 162150. One 2.4m by 1.2m TR26 board covers 2.88m². Three give 8.64m² per pack. Two packs provide only 17.28m², while three provide nine boards and 25.92m². Against the 24m² field, three packs leave a nominal 1.92m². This is the first quantity to test on the roofer’s layout. A balance on paper does not guarantee that a particular set of cuts will come out of nine boards.

Now suppose the approved design instead calls for the fully adhered system and 100mm TR27. Each 1.2m square covers 1.44m². Four in the selected pack therefore give 5.76m². Four packs cover 23.04m², which leaves the order short even on an outline without cuts. Five packs give twenty boards and 28.80m². The change from three packs to five follows from the product and pack format. It says nothing by itself about which quotation is cheaper or which roof performs better.

If the contractor specifies Powerdeck U, the same net area needs at least 34 of the 0.72m² boards on area alone. Thirty-three provide 23.76m² and thirty-four provide 24.48m². There is just 0.48m² between that minimum and the measured roof area. Do not enter “34 packs” into a basket on the strength of this sum. Send the board count to the supplier and ask them to return the corresponding order quantity, pack coverage and total supplied area for the thickness you need.

Why an area allowance can disappear on a drawing

Consider one run that is 4m long. With a board length of 2.4m you would have 1.6m left to cover after one full length, before considering the required joint arrangement. With a 1.2m board dimension, three full lengths would leave 0.4m. The useful remainder after a cut therefore changes with the format. Where a narrow strip or short offcut can be used depends on the approved layout. A larger board does not automatically produce less waste, particularly around a line of rooflights.

Ask for a sketch showing the pieces around the largest opening. It can be misleading to deduct the entire rooflight area from the order: a rooflight cut out of the middle of a board does not necessarily give you an offcut of the shape you need elsewhere. Conversely, charging for a full extra board at every corner can overstate the order if pieces can be paired. Mark reusable cuts on the sketch and have the roofer confirm the final number before you round up to complete packs.

Keep flat field boards separate from any tapered insulation on the schedule. A single thickness selected from a product dropdown cannot convey the sequence of a tapered layout. If the falls are formed using insulation, request the supplier’s layout and component list and have those checked against the outlets. If they are formed elsewhere in the construction, ask which flat boards comprise the field. This is also a useful moment to identify who is pricing the insulation at rooflight kerbs and other upstands.

What should be on comparable quotations?

Ask each supplier to show the manufacturer, full product reference, board thickness, face dimensions, boards per sales unit, number of units and total square metres. Put delivery on its own line. A price per board for a 2.88m² sheet is hard to compare with a price per board for a 0.72m² sheet. Divide the total material price by the total area supplied for a like-for-like rate. Keep the actual order total visible alongside it, because rounding up to full packs can change which quotation costs you more on a small extension.

Think about how the material will reach the place where the contractor wants it stored. A 2.4m board and a 1.2m square present different handling questions on a narrow side passage with a right-angle turn. Give the supplier your access measurements and confirm the delivery arrangement before booking labour. If the selected format is awkward, discuss a manufacturer-approved alternative format with the roofer. Changing the board type simply to get it through a gate can undo the earlier compatibility checks.

Questions worth asking before you order

Does the same thickness make two PIR boards interchangeable?

No. In the worked example the two Kingspan variants share a thickness but differ in intended waterproofing application, board size and pack coverage. Ask the designer to review any proposed substitution against the complete roof specification. If your original quote lists a particular membrane and insulation reference together, keep those two details together when requesting a revised price.

Can I use this calculation for insulation fitted from inside?

The example prices the main insulation layer of a warm roof above the deck. Insulating an existing flat roof from below changes the position of the insulation and raises different moisture-design questions. Have the existing construction assessed before choosing that route. Our overview of insulation types can help you distinguish the different materials in a specification.

Should the roof finish affect the board order?

Tell the designer if the finished roof is intended to carry a terrace surface. A walkway or paving layout brings additional layers and support details that need to be considered together. Our guide to promenade tiles on flat roofs explains why the finish needs its own layout. Counting the square metres of paving does not establish which insulation belongs beneath the waterproofing.

The order for the 24m² example

If the signed-off specification is the mechanically fixed single-ply example with 100mm TR26, the starting order is three packs of 162150, subject to the cutting plan. If the specified build-up is the adhered TR27 example, it is five packs of 162160 on the same basis. Put the contractor’s confirmed board count alongside those figures. That gives the merchant a precise item to supply and gives the roofer a clear record of what will turn up on site.

Ask JJ about flat roof board packs