Acoustic partition roll: will one pack cover eleven stud bays?
Eleven stud bays, each needing a 2.36 m drop, take 25.96 linear metres of acoustic partition roll. A pack containing two 13 m strips gives you 26 metres. Would you order one pack? If the drawing calls for a continuous piece in each bay, you would be one drop short. Each strip yields five complete drops and a 1.20 m offcut. The extra length you need is there, but it comes in two pieces.
That is the calculation worth doing before you order insulation for a partition. The square metres on the wrapper tell you how much material you are buying. A sketch of the frame tells you whether you can cut it into the pieces the job needs. Here is how to put the two together, using three rolls from our acoustic insulation range and a pencil-and-paper cutting list.
What does the wall detail actually ask for?
Start with the wall reference on the drawing. Two partitions in the same refurbishment might look identical on plan whilst having different linings or insulation. Write the wall reference, insulation name and thickness above your sketch. Where the drawing names a particular system, check its current specification before costing a substitute. A contractor asking for “some acoustic wool for the office” may already have a particular wall build-up priced into the job.
The roll sits inside the frame. In its APR 1200 data sheet, Isover describes the roll as contributing to the reduction of airborne sound when used within specified wall or floor constructions. A decibel figure for a complete partition belongs to that construction, including the linings and frame. It would be misleading to attach the figure to a roll in isolation. If the brief is about speech between a meeting room and a corridor, give the designer the wall and door details, as well as the name on the insulation pack. For a closer look at one lining option, see our guide to planning an acoustic refurbishment with GTEC dB Soundboard.
Read the three dimensions on the pack
Take the 50 mm Isover acoustic partition roll. Its thickness is 50 mm. Across the roll there are two 600 mm strips. Along the roll each strip measures 13 metres. Multiply 0.60 by 13 and you have 7.80 m² on one strip. Double that for the pack and you get the listed 15.60 m². The two strips are already included in that figure, so entering 31.20 m² in a spreadsheet would halve the order by mistake.
Changing the thickness on the same listing also changes the quantity calculation. The 25 mm Isover APR 1200, for instance, is listed at 24 m² a roll. Someone copying a previous order for 25 mm acoustic insulation could easily leave the old coverage in the estimate after selecting 50 mm. Put the thickness and coverage in the same cell or on the same line of your materials list. Check them together again when the basket shows the selected option.
Which roll works with the frame on the drawing?
For a second 50 mm option, the Superglass 50 mm acoustic insulation roll also gives you 15.60 m² in two 600 mm wide runs of 13 m. On the eleven-bay example the cutting calculation is identical. If the specification permits either product, you can use the same pack count to request comparable delivered quotations. If one is named, give the designer the exact proposed alternative before relying on the price difference.
A different frame layout changes what is worth comparing. The 100 mm Superglass Multi Acoustic Roll has a 1,200 mm nominal width with perforations for two 600 mm or three 400 mm strips. The Superglass size table gives the length as 10.10 m and the pack area as 12.12 m². That choice of strip widths is useful where drawings call for 100 mm insulation and show different stud spacings. Decide which widths you need before splitting the roll. Once a section has been divided into thirds, it cannot yield a continuous 600 mm wide piece.
| Selected product | Nominal strip layout | Pack area |
|---|---|---|
| Isover APR 1200, 50 mm | 2 × 600 mm by 13 m | 15.60 m² |
| Superglass APR, 50 mm | 2 × 600 mm by 13 m | 15.60 m² |
| Superglass Multi Acoustic, 100 mm | 1,200 mm, 2 × 600 mm or 3 × 400 mm by 10.10 m | 12.12 m² |
Measure bays on one face of the partition
Stand at one end and number each clear opening on your sketch. Record the height that needs filling and the clear width between the framing members. Stud centres are measured from the centre of one stud to the centre of the next. That number is useful for recognising the framing layout, but the gap at a corner, beside a door lining or at the end of the wall can be quite different. Follow the manufacturer's fitting guidance when translating those measurements into cut sizes.
A room plan with a six-metre line on it will not tell you how many short sections the carpenter has framed above a doorway. Mark those pieces individually. If there is a horizontal member part-way up a bay, give the upper and lower spaces their own measurements. Conversely, when estimating a single specified insulation layer, count the cavity once. A dryliner's estimate may include board to both faces and multiple layers of plasterboard. Copying that board area into the roll calculation can leave a considerable surplus.
One pack or two? Lay out the cuts
Return to the eleven full-height bays. Assume the drawing specifies 50 mm Isover APR 1200, the bay layout suits the 600 mm strip format and the measured drop is 2.36 m throughout. Lay out the first five drops against strip A. They take 11.80 m. Mark the remaining 1.20 m as A6. Repeat on strip B. At this point you can label ten bays with the strip they will come from. The eleventh is the one to discuss with the installer.
If continuous full-height pieces have been requested, two packs are needed for that layout. Before committing the second pack solely to one drop, check the other walls on the same job. Is there another run of the same specified partition still to be measured? Adding its cuts now gives you a sensible use for the balance and a more realistic total for the room. Keep the second pack on the list until the additional measurements or amended cutting detail are confirmed.
If the approved installation detail allows a joint in the last bay, two pieces of 1.18 m would add up to the required height. On paper, each comes out of a 1.20 m offcut. That leaves only 20 mm spare at each cut. Measure the final opening and the usable length of both pieces before promising a one-pack finish. An out-of-square head, a damaged end or a slightly taller last bay could use up that margin. This is a close cut that merits a site measurement.
Now change the drawing. Suppose there are ten full bays and two shorter openings, each needing a 0.45 m length of the same strip above a framed opening. Reserve one short piece from each 1.20 m tail. One pack then provides ten complete drops, two complete short pieces and two 0.75 m remnants. Those two short openings cost no extra pack. That outcome is much harder to spot if the only figure on your order sheet is a blanket percentage for waste.
Put the cut list to work when asking for a price
Ask each merchant to quote the same product, thickness and number of saleable packs to the same postcode. A price per square metre is helpful for comparing rates, but your invoice will reflect the quantity you can actually buy. A quote for one 15.60 m² pack against a quote for two looks attractive until someone has to source the missing full drop. Include any known delivery restriction and ask for the total with the VAT basis shown so both figures are comparable.
For the continuous-drop example, an order enquiry could read “Isover APR 1200, 50 mm, JJ code 151873, two packs at 15.60 m² each. Eleven drops at 2.36 m. Please confirm the delivered total and earliest delivery to our postcode.” The person receiving that enquiry can check the variant against your list. The person signing for the material can compare the wrapper with the order before it is opened and distributed between rooms.
Questions that come up before plasterboarding
Can I choose a thinner roll because it covers more wall?
Use the thickness stated for your wall. The 25 mm and 50 mm Isover options both come under APR 1200, but buying the one with greater coverage changes what goes into the cavity. If your supplier offers a different thickness, ask whoever specified the partition to review the change while the quote is still open. It is an easier decision to resolve before delivery than when the boards are waiting to go on.
Should spare pieces from different rooms go on the same list?
Yes, if they are the same specified product and thickness and their dimensions suit the remaining openings. Write usable width and length on the sketch next to the room where the piece is stored. “Half a roll upstairs” is surprisingly hard to allocate when a colleague needs five full-height drops downstairs. A remnant that is still full length but only 200 mm wide has a very different use from a short piece across the whole roll.
What should I check if the pack label and quotation disagree?
Keep the wrapper intact and check the manufacturer's name, product code, thickness and coverage against your order confirmation. Take a photograph that shows the dimensions and the label together. For a Superglass roll marked with several possible widths, establish which is the overall width and which are the perforated strip sizes. If the supplied pack gives a different length from the one used in the cut list, resolve the discrepancy before the first cut.
What to put on your final order
For the eleven-bay wall, the decision comes down to one opening. Ten full drops fit in one pack. The eleventh takes either an agreed joint with very little margin or a fresh strip from a second pack. Mark that decision beside bay eleven, carry the exact variant through to the basket and keep the sketch with the delivery note. Someone opening the material on Monday morning can then see why the two 1.20 m tails have been set aside.