Ideal Exclusive Horizontal Flue Terminal
The Ideal Exclusive Horizontal Flue Terminal is a 600mm-long horizontal flue kit designed for compatible Ideal Atlantic boilers. It provides a practical solution for routing the boiler flue horizontally through an external wall, with the flexibility to position the flue to the rear, left or right of the boiler.
Designed for a straightforward installation, the kit includes the key components required for a suitable horizontal flue arrangement. It offers a neat and practical way to complete the flue connection while maintaining the required installation configuration.
Flexible Horizontal Flue Installation
With its 600mm length, this horizontal flue kit is designed to provide flexibility when positioning a compatible boiler. The flue can be routed through the wall to the rear, left or right of the boiler, depending on the installation requirements and available space.
The included wall sealing components help provide a suitable finish around the flue where it passes through the wall. Always ensure the flue is installed in accordance with the boiler manufacturer's requirements and relevant regulations.
What's Included
The Ideal Exclusive Horizontal Flue Terminal kit contains:
- Flue terminal
- Flue turret
- Rubber terminal wall seal
- Cutting aid
- White wall seal
These components are supplied together to provide the main parts required for the specified horizontal flue installation.
Key Features
- 600mm-long horizontal flue kit
- Designed for compatible Ideal Atlantic boilers
- Suitable for rear, left or right flue installation through the wall
- Includes flue terminal
- Includes flue turret
- Includes rubber terminal wall seal
- Includes cutting aid
- Includes white wall seal
- Practical solution for horizontal boiler flue installation
Compatibility and Installation
The Ideal Exclusive Horizontal Flue Terminal is designed for use with compatible Ideal Atlantic boilers. Before purchasing, check the exact boiler model and flue requirements to ensure the kit is suitable for your installation.
Flue installation should be completed in accordance with the manufacturer's instructions and relevant building and gas safety requirements by a suitably qualified heating professional.
Available Variants
This is a boiler flue accessory, so door-specific variants such as door sizes, finishes, colours, glazing options and handing are not applicable. No additional variants were provided in the supplied Excel information.
Frequently Asked Questions
What is the Ideal Exclusive Horizontal Flue Terminal used for?
The kit is used to provide a horizontal flue connection for compatible Ideal Atlantic boilers, allowing the flue to pass through an external wall to the rear, left or right of the boiler.
How long is the Ideal Exclusive Horizontal Flue Terminal?
The horizontal flue kit is 600mm long, making it suitable for the specified horizontal flue installation.
What is included with the flue terminal kit?
The kit includes a flue terminal, flue turret, rubber terminal wall seal, cutting aid and white wall seal.