The Grant High Level Internal Adjustable Wall Bracket is designed to provide secure and flexible support for compatible Grant flue systems. It forms part of Grant's EZ-Flue range, which has been developed to make boiler and flue installations quicker and simpler while providing reliable performance, even in exposed installation conditions.
Available in two adjustment ranges, 50-90mm and 90-200mm, the bracket provides installers with flexibility when positioning and supporting the flue system.
Flexible Flue Installation
The Grant EZ-Flue system allows the flue to be extended both horizontally and vertically, providing greater freedom when planning an installation. Straight flue runs can also be adapted to create offsets using compatible 45° elbows and extensions, making it easier to work around obstacles.
The maximum total flue length is 10 metres. When additional 45° elbows are incorporated into the flue arrangement, 1 metre must be deducted from the maximum permitted length for each additional elbow used.
Quick and Simple Assembly
The EZ-Flue system features a unique connection arrangement designed to make assembly straightforward. The wider system also uses self-sealing ducts that do not require silicone or tape at the joints, helping simplify installation and create a secure connection.
The system is compatible with Grant boilers except External Modules, making it suitable for a broad selection of compatible Grant installations.
Available Adjustment Ranges
The Grant High Level Internal Adjustable Wall Bracket is available in two sizes. The 50-90mm adjustment range is suited to installations requiring a smaller adjustment, while the 90-200mm option provides a greater range where additional flexibility is needed.
Selecting the appropriate bracket allows the installer to accommodate the specific requirements of the flue installation.
Key Features
- Available in 50-90mm and 90-200mm adjustment ranges
- Supplied as a complete kit
- Designed for compatible Grant EZ-Flue systems
- Flue can be extended horizontally and vertically
- Maximum total flue length of 10 metres
- Deduct 1 metre from the maximum length for each additional 45° elbow used
- 45° elbows and extensions can be used to create offsets in straight flue runs
- Unique connection system designed for easy assembly
- EZ-Flue system features self-sealing ducts requiring no silicone or tape at joints
- Compatible with Grant boilers except External Modules
- Designed to support quick and straightforward installation
Frequently Asked Questions
What adjustment ranges are available for the Grant High Level Internal Adjustable Wall Bracket?
The bracket is available in two adjustment ranges: 50-90mm and 90-200mm. The appropriate option can be selected according to the support and positioning requirements of the flue installation.
What is the maximum total flue length?
The maximum total flue length is 10 metres. For every additional 45° elbow used in the installation, 1 metre must be deducted from the maximum permitted flue length.
Can the Grant EZ-Flue system be extended both horizontally and vertically?
Yes. The system can be extended horizontally and vertically, and compatible 45° elbows and extensions can also be used to create offsets in straight flue runs. The system should always be installed in accordance with the relevant Grant installation requirements.