{"product_id":"grant-aerona-installation-pack-c-direct-for-non-pre-plumbed-cylinders","title":"Grant Aerona Installation Pack C - Direct for Non-Pre-Plumbed Cylinders","description":"\u003ch3\u003eGrant Aerona Installation Pack C - Direct for Non-Pre-Plumbed Cylinders\u003c\/h3\u003e\n\nThe Grant Aerona3 Installation Pack C is designed to make the installation of compatible direct air source heat pump systems simpler and more convenient. It is specifically intended for Grant Aerona3 systems using a direct configuration with a non-pre-plumbed cylinder and brings together a range of essential components in one complete package.\n\n\u003ch3\u003eComplete Installation Pack\u003c\/h3\u003e\n\nThe pack includes a combined volumiser\/low loss header, domestic hot water programmer, flexi foot kit, Mag One filter, 18-litre sealed system kit and air-conditioning isolator. It also includes a 7-day immersion programmer, heat pump wiring interface, hot water priority relay, 28mm 3-port diverter valve and cylinder sensor.\n\nBy supplying these components together, the Installation Pack C can help installers streamline the process of sourcing the accessories required for a compatible system configuration.\n\n\u003ch3\u003eDesigned for Direct Systems\u003c\/h3\u003e\n\nThis installation pack is specifically suitable for Grant direct systems using non-pre-plumbed cylinders. The components have been selected to support this particular system arrangement, helping provide a convenient installation solution for compatible Aerona3 heat pump projects.\n\n\u003ch3\u003eCompatible with Aerona3 Heat Pumps\u003c\/h3\u003e\n\nThe sealed system kit supplied with the pack is suitable for use with all Grant Aerona3 heat pumps. However, the complete Installation Pack C is designed for a specific direct system configuration, so the complete system setup should be checked for compatibility before ordering.\n\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\n\u003cul\u003e \u003cli\u003eGrant Aerona3 Installation Pack C\u003c\/li\u003e \u003cli\u003eDesigned for direct systems\u003c\/li\u003e \u003cli\u003eSuitable for non-pre-plumbed cylinders\u003c\/li\u003e \u003cli\u003eCompatible sealed system kit for all Aerona3 heat pumps\u003c\/li\u003e \u003cli\u003eCombined volumiser\/low loss header included\u003c\/li\u003e \u003cli\u003eDomestic hot water programmer included\u003c\/li\u003e \u003cli\u003eFlexi foot kit included\u003c\/li\u003e \u003cli\u003eMag One filter included\u003c\/li\u003e \u003cli\u003e18-litre sealed system kit included\u003c\/li\u003e \u003cli\u003eAir-conditioning isolator included\u003c\/li\u003e \u003cli\u003e7-day immersion programmer included\u003c\/li\u003e \u003cli\u003eHeat pump wiring interface included\u003c\/li\u003e \u003cli\u003eHot water priority relay included\u003c\/li\u003e \u003cli\u003e28mm 3-port diverter valve included\u003c\/li\u003e \u003cli\u003eCylinder sensor included\u003c\/li\u003e \u003cli\u003eDesigned to simplify installation for installers\u003c\/li\u003e \u003cli\u003eSpecific to direct systems with non-pre-plumbed cylinders\u003c\/li\u003e \u003c\/ul\u003e\n\n\u003ch3\u003eInstallation and Compatibility\u003c\/h3\u003e\n\nThe Grant Aerona3 Installation Pack C is intended for a specific system configuration, so it is important to confirm that the planned installation uses a compatible direct system and non-pre-plumbed cylinder. Installation should be carried out by a suitably qualified professional in accordance with the manufacturer's instructions and applicable requirements.\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat type of system is the Grant Aerona3 Installation Pack C designed for?\u003c\/h4\u003e\n\nThe Installation Pack C is designed for Grant Aerona3 direct systems using non-pre-plumbed cylinders. It brings together components specifically selected for this type of installation.\n\n\u003ch4\u003eWhat components are included in Installation Pack C?\u003c\/h4\u003e\n\nThe pack includes a combined volumiser\/low loss header, domestic hot water programmer, flexi foot kit, Mag One filter, 18-litre sealed system kit, air-conditioning isolator, 7-day immersion programmer, heat pump wiring interface, hot water priority relay, 28mm 3-port diverter valve and cylinder sensor.\n\n\u003ch4\u003eIs the sealed system kit suitable for all Grant Aerona3 heat pumps?\u003c\/h4\u003e\n\nYes. The supplied sealed system kit is suitable for all Grant Aerona3 heat pumps. However, the complete Installation Pack C is intended for a direct system with a non-pre-plumbed cylinder, so the full installation configuration should be checked before purchase.","brand":"Grant","offers":[{"title":"Default Title","offer_id":55209961947478,"sku":"181674","price":958.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0905\/4509\/4998\/files\/grant-aerona-installation-pack-c-direct-for-non-pre-plumbed-cylinders-1483844.jpg?v=1788683353","url":"https:\/\/jjbuildingmaterials.co.uk\/products\/grant-aerona-installation-pack-c-direct-for-non-pre-plumbed-cylinders","provider":"JJ Building Materials","version":"1.0","type":"link"}